Re: sa750 fuel tank question.


[ Follow Ups ] [ Post Followup ] [ Starduster Bulletin Board ] [ FAQ ]

Posted by Dan Benkert (24.111.1.182) on October 10, 2005 at 20:43:36:

In Reply to: sa750 fuel tank question. posted by Randy on October 10, 2005 at 08:52:28:

Hi guys, it's been a while since I installed my fuel system but I recall that of the 3 small outlets at the top, only 2 were intended as vents. Upright vent was just a port to be routed down to the belly. Inverted vent had a line to the bottom of the tank and was routed to the top wing. The third fitting was used in Continental injection installations for the fuel return line. Lyc guys just plugged it. My center section tank runs thru a shutoff valve to a Tee at the flop tube. The fitting on the aft side of the tank should be for sumping purposes. I think there is a diagram of this in the Starduster history which I will look for unless someone else finds it first. Dan


Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments:

Optional Link URL:
Link Title:
Optional Image URL:


[ Follow Ups ] [ Post Followup ] [ Starduster Bulletin Board ] [ FAQ ]